| Watermakers/Parts | Service/Support | Locations | News | Contact | Home |
|
![]() Fort Lauderdale · Palm Beach · Savannah |
5,500 to 21,000 U.S. gal. (20,820 to 79,493 litres) per day
229 to 875 U.S. gal. (867 to 3,312 litres) per hour
![]()
![]() |
|||
| Small hotels, large villas, oil platforms, and small cruise ships with 100 to 200 passengers aboard require from 5,500 to 21,000 U.S. gallons (20,820 to 79,493 litres) of fresh water per day. Sold as a complete package, Sea Recovery offers the"Tasman Sea" Series to satisfy these watermaking requirements. Found throughout the world, these easily maintained reverse osmosis desalinators produce large quantities of fresh water with unsurpassed reliability. The reason can be traced to Sea Recovery's unique engineering abilities and total commitment to high quality products. Sea Recovery delivers complete R.O. systems, ready to produce water immediately after installation. All necessary plumbing for onboard use is also included. | |||
To see the various accessories available for the Tasman Seas, click on Accessories.
|
Features
|
|
|
||||
| Specifications | ||
RATED PERFORMANCE / PRODUCT WATER PRODUCED:
+-15% at 820 PSIG / 56 BAR, 77oF / 25oC & 35,000 PPM TDS typical sea water
|
Model #
|
Per Hour
|
Per Day
|
Weight of System
|
|
|
21m3 HR/S1
38m3 HR/S1 53m3 HR/S1 64m3 HR/D1 72m3 HR/D1 79m3 HR/D1 38m3 HR/S2 64m3 HR/S2 79m3 HR/S2 |
229 gal/867 lit
417 gal/1,577 lit 583 gal/2,208 lit 708 gal/2,681 lit 792 gal/2,997 lit 875 gal/3,312 lit 417 gal/1,577 lit 708 gal/2,681 lit 875 gal/3,312 lit |
5,500 gal /20,820 lit
10,000 gal/37,854 lit 14,000 gal/52,996 lit 17,000 gal/64,352 lit 19,000 gal/71,923 lit 21,000 gal/79,493 lit 10,000 gal/37,854 lit 17,000 gal/64,352 lit 21,000 gal/79,493 lit |
1900 lbs/864 Kg
2000 lbs/909 Kg 2100 lbs/954 Kg 2300 lbs/1045 Kg 2400 lbs/1090 Kg 2500 lbs/1136 Kg 2000 lbs/909 Kg 2200 lbs/1000 Kg 2400 lbs/1090 Kg |


SALT REJECTION (CHLORIDE ION): Minimum 99.2%, Average 99.5%
PRODUCT WATER TEMPERATURE: Ambient to feed water temperature
SALINITY MONITORING: Automatic electronic monitoring. Temperature compensated with solid state "DOT LED" continuous readout in micromhos per cm3 and of a fail-safe design.
| Feed Water: | Minimum: | 15 psi / 1 bar / 1 Kg/cm2 |
| Maximum: | 50 psi / 3.45 bar / 3.5 Kg/cm2 |
| Inlet: | 1-1/2" Flange |
| Brine: | 1-1/2" Flange |
| Product: | 1" Flange |
| Hz | VAC | HP | FLA | LRA |
| 50 | 220 | 30 & 2 | 56 | 390 |
| 50 | 380 | 30 & 2 | 28 | 198 |
| 50 | 415 | 30 & 2 | 26 | 180 |
| 60 | 208 | 30 & 2 | 57 | 390 |
| 60 | 230 | 30 & 2 | 52 | 370 |
| 60 | 460 | 30 & 2 | 26 | 185 |
|
Hz
|
VAC
|
HP
|
FLA
|
LRA
|
Hz
|
VAC
|
HP
|
FLA
|
LRA
|
|
|
50
|
220
|
1.5
|
6
|
38
|
50
|
220
|
2
|
6
|
44
|
|
|
50
|
380
|
1.5
|
3
|
19
|
50
|
380
|
2
|
3
|
22
|
|
|
50
|
415
|
1.5
|
3
|
18
|
50
|
415
|
2
|
3
|
20
|
|
|
60
|
208
|
1.5
|
6
|
38
|
60
|
208
|
2
|
6
|
42
|
|
|
60
|
230
|
1.5
|
5
|
34
|
60
|
230
|
2
|
6
|
38
|
|
|
60
|
460
|
1.5
|
2.5
|
17
|
60
|
460
|
2
|
3
|
19
|
|
Hz
|
VAC
|
HP
|
FLA
|
LRA
|
Hz
|
VAC
|
HP
|
FLA
|
LRA
|
|
|
50
|
220
|
3
|
8
|
64
|
50
|
220
|
5
|
13
|
108
|
|
|
50
|
380
|
3
|
4
|
32
|
50
|
380
|
5
|
7
|
54
|
|
|
50
|
415
|
3
|
4
|
30
|
50
|
415
|
5
|
7
|
52
|
|
|
60
|
208
|
3
|
9
|
64
|
60
|
208
|
5
|
14
|
110
|
|
|
60
|
230
|
3
|
8
|
58
|
60
|
230
|
5
|
13
|
100
|
|
|
60
|
460
|
3
|
4
|
29
|
60
|
460
|
5
|
7
|
50
|
RECOMMENDED CIRCUIT BREAKER: The actual final system configuration may have a large or different size Feed Water Pump and Booster Pump therefore size your Circuit Breaker accordingly. The below chart is an approximation assuming 3 horse power Feed Water and 3 horse power Booster Pumps.
|
Operating Voltage Hz & Phase
|
Recommended Circuit Breaker Size |
Recommended Circuit Breaker Size |
||
|
220 VAC, 50 Hz, 3 Phase |
90 Amperes |
|
75 Amperes |
Back to the Watermakers Catalog
|