Watermakers/Parts Service/Support Locations News Contact Home
Beard Marine Watermakers and Purification Beard Marine reverse osmosis watermakers
Fort Lauderdale · Palm Beach · Savannah
 
 

Aqua Whisper 170 & 350

170 & 350 U.S. gal. (644 & 1,325 litres) per day
7 & 15 U.S. gal. (27 & 55 litres) per hour



To see the various accessories available for the AW 170 & 350, click on Accessories.


Specifications

PERFORMANCE:
RATED PERFORMANCE / PRODUCT WATER PRODUCED:
+-15% at 850 PSI / 59 BAR, 77oF / 25oC & 35,000 PPM TDS typical sea water

Model #
Per Hour
Per Day
Weight of System
AW 170 & 350
7 & 15 gal/27 & 55 lit

170 & 350 gal /644 & 1,325 lit

105 lbs/48 Kg

AW 170 reverse osmosis desalinator diagram

SALT REJECTION (CHLORIDE ION): Minimum 99.2%, Average 99.4%

PRODUCT WATER TEMPERATURE: Ambient to feed water temperature

SALINITY MONITORING: Automatic electronic monitoring. Temperature compensated with the solid state continuous "Bar LED" readout. The salinity monitoring components of the system give a continuous TDS readout in micromhos per cubic centimeter, are temperature compensated and of a fail safe design.

SALINITY RANGE: Designed for Seawater use up to 50,000 PPM TDS (NaCl) (typical seawater salinity is 35,000 ppm)

TEMPERATURE RANGE: Max. 122oF / 33oC, Min. 33oF / .5oC

SYSTEM FEED WATER: FLOW: 50 Hz, 4.2 gpm / 1.59 lpm; 60 Hz, .5 gpm/1.89 lpm

REVERSE OSMOSIS MEMBRANE: Selected High Rejection/High Yield aromatic tri-polyamid, thin film composite, spiral wound, single pass, high rejection reverse osmosis membrane element.

CHLORINE TOLERANCE: 0.1 PPM

pH RANGE: 3-11 (typical seawater pH is 8)

SYSTEM PRESSURE: FEED WATER: Maximum 30 psi / 2.07 bar / 2.11 Kg/cm2

SYSTEM OPERATION: Seawater nominal 850 psi / 59 bar / 59.7 Kg/cm2 Brackish Varies w/PPM

EXTERNAL INSTALLATION WATER CONNECTIONS: Pipe sizes to be supplied by the installer for connection of the Sea Recovery supplied components.

Feed Inlet: 3/8" Tube (Parker Fast & Tite Fittings)
Brine Discharge: 3/8" Tube (Parker Fast & Tite Fittings)
Product: 1/4" Tube (Parker Fast & Tite Fittings)

ELECTRICAL POWER REQUIREMENTS: (HP = Horse Power; FLA = Full Load Amperes; LRA = Locked Rotor Amperes - Start Up)

Alternating Current Systems:

Hz VAC HP FLA LRA
50     110         .333 6 26
50 220 .333 3 13
60 115 .333 6 26
60 230 .333 3 13

Booster Pump Motors:

Hz VAC HP FLA LRA
50/60 115 .125 4 20
50/60 220/230 .125 2 10

Direct Current Systems:

High Pressure Motor             Booster Pump Motor

VDC HP FLA VDC HP FLA
12 .33 29   12 .125 3
24 .33 14 24 .125 2

RECOMMENDED CIRCUIT BREAKER: The final system configuration may have a large or different size Booster Pump therefore size your Circuit Breaker accordingly. The below chart is an approximation assuming standard pumps.

Operating Voltage Hz & Phase

Recommended Circuit Breaker Size

12 VDC
24 VDC
115 VAC
230 VAC

40 Amperes
20 Amperes
10 Amperes
5-7.5 Amperes


Back to the Watermakers Catalog

 
Marine Industries Association of South Florida Use the email links below or our Inquiry Form for more info.
We offer our services in English, Portuguese, and Spanish for your convenience.

{ Home | Watermakers/Parts | Service | Ft. Laud. | Palm Beach | Savannah }
{ News | Contact | Email | Links }

 
 
Fort Lauderdale 954-463-2288 Toll Free: 800-663-7561 [email]
Palm Beaches 561-881-9598 Toll Free: 800-348-9637 [email]
Savannah, GA 912-356-5222 Toll Free: 800-286-2674 [email]