Performance:
Rated Performance / Product Water Produced:
+-15% at 820 PSI / 56.5 bar, 77oF / 25oC & 35,000 PPM TDS typical sea water
| Model # |
Per Hour |
Per Day |
AM 450-1
AM 700-1
AM 900-1
AM 900-2
AM 1400-2
AM 1800-2 |
19 gal/71 lit
29 gal/110 lit
38 gal/142 lit
38 gal/142 lit
58 gal/221 lit
75 gal/284 lit |
450 gal /1,703 lit
700 gal/2,650 lit
900 gal/3,407 lit
900 gal/3,407 lit
1400 gal/5,300 lit
1800 gal/6,814 lit |
Salt Rejection (Chloride Ion): Minimum 99.2%, Average 99.4%
Product Water Temperature: Ambient to feed water temperature
Pressure Adjustment: Automatically controlled
Salinity Monitoring: Automatic electronic monitoring. Temperature compensated with the digital continuous readout. The salinity monitoring components of the system give a continuous TDS readout in ppm (parts per million), are temperature compensated, and of a fail safe design.
Salinity Range: Designed for seawater use up to 50,000 PPM TDS (NaCl) (typical seawater salinity is 35,000 ppm)
Temperature Range: Max. 122oF / 50oC, Min. 33oF / .5oC
System Feed Water: Flow: 4.5 gpm / 17 lpm
(depending on system)
Reverse Osmosis Membrane: Selected High Rejection/High Yield aromatic tri-polyamid, thin film composite, spiral wound, single pass, high rejection reverse osmosis membrane element.
Chlorine Tolerance: 0.1 PPM
pH Range: 3-11 (typical seawater pH is 8)
System Pressure: Feed Water: Maximum 35 psi / 2.41 bar / 2.46 Kg/cm2
System Operation: Seawater nominal 820 psi / 56.5 bar / 57.66 Kg/cm2
Weight:
|
|
Compact |
AM 450-1
AM 700-1
AM 900-1
AM 900-2
AM 1400-2
AM 1800-2
|
137 lbs/63 Kg
140 lbs/64 Kg
142 lbs/65 Kg
149 lbs/68 Kg
155 lbs/71 Kg
160 lbs/73 Kg |
142 lbs/65 Kg
145 lbs/66 Kg
147 lbs/67 Kg
154 lbs/70 Kg
160 lbs/73 Kg
165 lbs/75 Kg |
External Installation Water Connections:
Pipe sizes to be supplied by the installer for connection of the Sea Recovery supplied components.
The below pipe threads are all American Standard.
| Feed Inlet: |
3/4" FNPT Female National Pipe Thread |
| Brine Discharge: |
3/4" FNPT Female National Pipe Thread |
| Product: |
3/8" MNPT Male National Pipe Thread |
Electrical Requirements: (HP = Horse Power; FLA = Full Load Amperes; LRA = Locked Rotor Amperes - Start Up)
High Pressure Pump Electric Motor:
| Phase |
Hz |
VAC |
HP |
FLA |
LRA |
| Single |
50 |
110 |
3.0 |
23 |
136 |
| Single |
50 |
220 |
3.0 |
11 |
68 |
| Three |
50 |
220 |
3.0 |
9 |
40 |
| Three |
50 |
380 |
3.0 |
5 |
20 |
| Single |
60 |
115 |
3.0 |
25 |
136 |
| Single |
60 |
230 |
3.0 |
12 |
68 |
| Three |
60 |
230 |
3.0 |
8 |
35 |
| Three |
60 |
460 |
3.0 |
4 |
18 |
Booster Pump & Feed Water Electric Motors:
| Phase |
Hz |
VAC |
HP |
FLA |
LRA |
| Single |
50/60 |
115 |
.5 |
7.4 |
34 |
| Single |
50/60 |
220/230 |
.5 |
3.7 |
17 |
| Three |
50/60 |
220/230 |
.5 |
2 |
12 |
| Three |
50/60 |
380/460 |
.5 |
1 |
6 |
Recommended Circuit Breaker: The final system configuration may have a large or different size Booster Pump therefore size your Circuit Breaker accordingly. The below chart is an approximation assuming standard pumps.
Operating Voltage Hz & Phase |
|
Rec. Circuit Breaker Size
|
115 VAC, 50/60 Hz, 1 Phase
230 VAC, 50/60 Hz, 1 Phase
208/230 VAC, 50/60 Hz, 3 Phase
380 VAC, 50/60 Hz, 3 Phase
460 VAC, 50/60 Hz, 3 Phase
|
|
40 Amperes
20 Amperes
10 Amperes
7.5 Amperes